Oversize part
Flag parts with any dimension > 3000mm -- machine capacity concern.
View check10 checks and profiles
CAD integrity, handling and general screening checks.
10 checks found
Flag parts with any dimension > 3000mm -- machine capacity concern.
View checkFlag STEP files with more than one disconnected solid body. Silent when the bodies overlap (PRU-071) or when every extra body is a loose plug inside a cutout of the sheet while the cutting rules run (PRU-087).
View checkFlag parts heavier than 25kg -- needs mechanical handling.
View checkFlag parts whose largest bounding-box dimension is below practical handling size.
View checkB-rep validity
View checkSurface-only files
View checkOpen boundaries and non-manifold edges
View checkNon-positive solid volume
View checkPositive-volume intersections between bodies
View checkContinuous fixed-orientation axial box/cylinder envelope against declared stationary STEP solids, after complete moving-solid containment proof. Conservative interference INFO; contact, incomplete bodies or kernel failure unassessed. No tool rotation, cutting or full process feasibility.
View checkNo matching check found. Try another search term or a check ID.