Prufi
PRU-066Geometry check

Open or non-manifold edges

Scope and limits

Open boundaries and non-manifold edges

Standards and references

No standards reference is assigned to this check. The scope described above applies.

STEP examples for this check

Geometry preview: Open surface: no solid

Sheet metal · CC0-1.0

Open surface: no solid

Model example

This single 20 × 30 mm sheet has zero thickness and four open edges. Rotate it to see that there are no side walls or enclosed volume.

Dimensions (approx.): 20 × 30 × 0 mm

Expected check result

PRU-065 (error) should report the missing solid. The open edges are the same cause, so PRU-066 stays silent.

Finding expected

PRU-065

No finding expected

PRU-066