Prufi
PRU-310Geometry check

Declared motion envelope interference

Machining · Sheet metal · Casting · Additive manufacturing · Hot-dip galvanizing

Scope and limits

Continuous fixed-orientation axial box/cylinder envelope against declared stationary STEP solids, after complete moving-solid containment proof. Conservative interference INFO; contact, incomplete bodies or kernel failure unassessed. No tool rotation, cutting or full process feasibility.

Standards and references

OCCT-7.7.2-MOTION

Open CASCADE 7.7.2 modeling algorithms: declared axial envelope motion

Source scope
Kernel construction, Boolean and distance APIs used for exact axial box/cylinder envelope sweeps; mathematical geometric screening, not a manufacturing standard.
Implementation in Prufi
PRU310 checks complete supplied moving-solid containment and continuous declared envelope clearance against selected stationary solids. Contact and uncertain geometry unassessed; envelope interference advisory.

STEP examples for this check

No public STEP example is currently assigned to this check.

Browse all public examples