Prufi
PRU-073Standard scope

Flame cutting: scope of checks

Flame cutting

Scope and limits

ISO 9013 flame thickness scope

Standards and references

ISO 9013:2017

Thermal cutting — Classification, geometrical specification and quality tolerances

Source scope
Public abstract lists laser cutting at 0.5–32 mm, plasma at 0.5–150 mm and flame cutting at 3–300 mm.
Implementation in Prufi
Published laser, plasma and flame thickness ranges are screened for orthogonal rectangular blanks and verified flat constant extrusions with through-holes, slots or planar/cylindrical outlines. Blind, stepped, tapered and folded stock remains unassessed. Explicit process selection only; no surface-quality tolerances or conformity assessment.

STEP examples for this check

Geometry preview: Flame stock: 200 mm

Flame cutting · CC0-1.0

Flame stock: 200 mm

Process scope example

Inspect the 200 mm stock edge. Selected process: flame; the published ISO 9013 thickness scope is 3–300 mm. The shape itself is a valid blank.

Dimensions (approx.): 1,200 × 1,400 × 200 mm

Expected check result

PRU-073: no scope notice expected; this does not establish cut quality.

No finding expected

PRU-073

Compare: Flame stock: 320 mm
Geometry preview: Flame stock: 320 mm

Flame cutting · CC0-1.0

Flame stock: 320 mm

Process scope example

Inspect the 320 mm stock edge. Selected process: flame; the published ISO 9013 thickness scope is 3–300 mm. The shape itself is a valid blank.

Dimensions (approx.): 1,920 × 2,240 × 320 mm

Expected check result

PRU-073: expect an informational scope notice, not a manufacturing rejection.

Finding expected

PRU-073

Compare: Flame stock: 200 mm