review-nc-heat-evidenceSupplied evidence required
Supplied NC heat and sequence histories
Offline review with additional files and records
Scope and limits
Compares complete controller events and calibrated thermal-site histories with independently supplied process/sequence/temperature limits.
This review is available through the separate offline tools. It does not run automatically when you upload a STEP file and requires the additional inputs described below.
Required inputs
Original NC/exports, complete ordered cut/pierce/dwell/idle histories, thermal sites, setup/material/fixture and qualified calibrated limits.
Assessment limits
Normalized complete-event contract only; no general NC dialect parser, heat-transfer solver or verification of actual delivered energy/execution.