review-filling-result-evidenceSupplied evidence required
Supplied finite filling results
Offline review with additional files and records
Scope and limits
Checks complete supplied cavity/runner/gate tetrahedra and final filling, pressure and temperature fields.
This review is available through the separate offline tools. It does not run automatically when you upload a STEP file and requires the additional inputs described below.
Required inputs
Actual polyhedral CAD regions, positive conforming tetrahedra, material card, solver/deck/process provenance and qualified result limits.
Assessment limits
Bounded supplied final-state results only; no filling solver, shape-only flow inference or proof of physical cavity filling.