Prufi
PRU-125Declared input

Flange too short for declared V die

Sheet metal

Scope and limits

Outside flange dimension >=0.7 actual die opening, preliminary screen for a 90-degree single rectangular air bend.

Standards and references

ADH-MIN-FLANGE-2026

ADH — Press Brake Minimum Flange Length

Source scope
Preliminary flange support for standard 90-degree air bending with the actual selected V opening.
Implementation in Prufi
Section: Start With 0.7 Times the V-Die Opening for a 90-Degree Air Bend. Compare the outside mould-line flange dimension with 0.7 V for an exact single rectangular bend only. Preliminary supplier guideline; die shoulders, tooling wear, angle changes and elastic effects remain unassessed.

STEP examples for this check

No public STEP example is currently assigned to this check.

Browse all public examples