Prufi
PRU-122Declared input

Selected clinch tool edge distance

Sheet metal · Joining

Scope and limits

Selected clinch tool edge distance

Standards and references

BTM-SECTION-D:2017-02-17-Rev20

BTM Engineering Standards Section D, revision 20 (2017-02-17), printed page 7

Source scope
Single TL-3.8-940 (794600AE) or TL-3.8-3B (796900A) Tog-L-Loc joint.
Implementation in Prufi
WARN centre-to-part boundary below 3.8 mm as explicitly labelled EDGE. No bend/die/stripper access or multi-joint qualification. Planar contact edges include holes conservatively.

STEP examples for this check

No public STEP example is currently assigned to this check.

Browse all public examples