ISO 9013:2017
Thermal cutting — Classification, geometrical specification and quality tolerances
- Source scope
- Public abstract lists laser cutting at 0.5–32 mm, plasma at 0.5–150 mm and flame cutting at 3–300 mm.
- Implementation in Prufi
- Published laser, plasma and flame thickness ranges are screened for orthogonal rectangular blanks and verified flat constant extrusions with through-holes, slots or planar/cylindrical outlines. Blind, stepped, tapered and folded stock remains unassessed. Explicit process selection only; no surface-quality tolerances or conformity assessment.